1 / 3 · Electrical room
01
Electrical & Control Rooms
Dedicated Space for Critical Electrical Systems
Our modular electrical and control rooms provide a controlled, organized environment for electrical distribution, instrumentation and automation systems. Unit layouts can be developed around cabinet dimensions, operating clearances, cable routes, equipment heat loads and maintenance requirements.
Typical applications: Electrical rooms · Local Equipment Rooms (LER) · Local Control Rooms (LCR) · PLC and instrumentation rooms
Available design formats
| Base format | External dimensions: L × W × H | Typical layout approach |
|---|---|---|
| 20 ft standard | 6,058 × 2,438 × 2,591 mm | Compact single-room arrangement |
| 40 ft standard | 12,192 × 2,438 × 2,591 mm | Longer cabinet line and access space |
| 40 ft high cube | 12,192 × 2,438 × 2,896 mm | Additional nominal height for services |
| Custom-built module | As designed | Project-specific footprint and height |
Detailed technical specifications
| Item | Technical specification / configuration |
|---|---|
| Main structure | Engineered steel frame or modified container structure, designed for the finished unit and its loads |
| Structural material | Steel grade and section sizes selected through structural design |
| External walls | Weather-resistant steel enclosure or engineered insulated wall assembly |
| Internal wall finish | Suitable lining selected for the operating environment and required fire performance |
| Roof | Weather-resistant construction with insulation and drainage provisions as required |
| Insulation | Type and thickness selected from thermal, condensation and fire requirements |
| Flooring | Load-rated floor designed for equipment point loads and maintenance access |
| Equipment mounting | Engineered cabinet bases, supports and anchoring arrangements |
| Personnel door | Size, swing and hardware selected for access and escape requirements |
| Equipment access | Removable panels or larger openings where cabinet installation requires them |
| Electrical supply | Voltage, phase, frequency and available fault level defined by project electrical data |
| Distribution | Main and auxiliary distribution arranged according to connected loads |
| Earthing | Protective earthing and bonding according to the electrical design |
| Cable routing | Floor or wall entries, cable trays and segregated routes as required |
| Lighting | General, task and emergency lighting according to the room design |
| HVAC | Capacity calculated from equipment heat rejection, ambient conditions and envelope heat gain |
| Ventilation | Provided where required by the equipment and cooling strategy |
| Fire protection | Detection, alarm and suppression provisions according to the project fire assessment |
| Monitoring | Temperature, humidity or other monitoring where specified |
| External coating | Surface preparation and coating system selected for site exposure |
| Transport and lifting | Engineered for the completed unit's weight and centre of gravity |